24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator
24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

Composite post insulator is a kind of silicone rubber apparatus insulators. Its design consists of a resin impregnated f

Send your inquiry

DESCRIPTION

Basic Info.
Model NO. Line Post Insulator
Size of Bearing Capacity 40-550kn
Certification ISO9001
Color Grey
Brand Wishpower
Transport Package Box
Specification composite insulator
Trademark Wishpower
Origin China
HS Code 85469000
Production Capacity 50000 Pieces/Year
Product Description
  • DESCRIPTION

Composite post insulator is a kind of silicone rubber apparatus insulators. Its design consists of a resin impregnated fiberglass core, a polymeric housing and metallic end fitting attachment devices. Composite station post insulator applies ANSI C29.19 international standard. Polymer or composite station post insulator can have many mechanical loadings: compression, cantilever, tensile and/or torsion, depending on the application.

69 kV Station Post Insulator Applications:

Station post insulators are typically used in all standard high-voltage switch and bus applications. They meet or exceed all ANSI standards in both electrical and mechanical characteristics for their voltage class.

69 kV Station Post Insulator Features:

  • Hydrophobic, silicone polymer for improved contamination performance
  • Over-molded design to prevent moisture ingress
  • Lightweight, vandalism resistant and price competitive compared to porcelain

69 kV Station Post Insulator Specifications:

RATING (kV)BIL (kV)TR #HEIGHTBOLT CIRCLE
7.5952027.5″3
1511020510″3
1511022512″5
2315020814″3
34.520021018″3
34.520023120″5
4625021422″3
4625026724″5
6935021630″3
6935027830″5

Line Post Insulator Applications:

Line Post Insulators are used on overhead transmission lines operating at and under 69 kV. These insulators are commonly installed either vertically or horizontally on metal or wooden structures to support the conductor. Also, these insulators are used to support high voltage conductor jumpers or leads.

Line Post Insulator Features:

  • Secure and reliable operation on high mechanical strength.
  • Compact design and light in weight which is convenient for transportation.
  • Good anti-vibration capability. Good anti-moisture capability.
  • Good electric performances.
  • High anti-aging performances which is perfect for utilization under conditions of high altitude.
  • Easy for maintenance.

Line Post Insulator Specifications:

Customized according to customer needs
Wishpower professionally designs and manufacture the following products: composite insulators series used on HV transmission and distribution line, HDPE insulator,HDPE Pin insulator,composite insulators series used on electrified railway catenary flexible suspension section insulators used on the subway, rigid suspension insulators used on the subway, composite dry-type insulation capacitance bushing series, composite dry type transformer capacitance bushing series, composite dry type through-wall capacitance bushing series, composite housed zinc oxide arrester series, composite subway evacuation platform series, composite subway cable mounting bracket series, composite three-rail shield series used on electrified railway, composite insulation climb ladder series used on live working, high polymer interphase spacer, etc. electrical equipment.

24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

Wishpower is a full-service supplier of power products, including insulator, fuse cutout, surge arrester and line construction hardware.

Raw Material / Parts Inspection

Silicone Rubber test
The produciton and inspection of Electric insulation silicone rubberSilicone rubber standard: DL/T 376-2010Electrical performance1. Volume resistivity ≥1.0 X 10 Ω·m;2.Surface resistivity ≥1.0 X 10 Ω;3.Breakdown strength AC ≥20KV/mm, DC≥30KV/mm;4.Tracking and electrical erosion ≥TMA4.5 grade;5,Hydrophobicity satisfy the requirement on standard 6.2

Mechanical performance
1,Tearing strength(rectangularity)≥10kN/m;
2,Mechanical breaking strength ≥4MPa;
3,Tensile elongation ≥150%;
4,Shaw intensity ≥50Shore A;
5,Flammability≥ FV-0

Aging resistance
1. Ageing test for 1,000 hours

24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

Metal Fitting test
Hardware inspection procedures:Ball and socket(IEC 60120):1.Appearance2.Dimension inspection3.Zinc layer thickness inspection4.Hardness inspection5.go no-go gauge(ball and socket)6.Locking system inspection

24kv Composite Station Post Insulator, Silicon Insulator, Polymer Insulator

Fiberglass Rod / Tube test
Wish rods will be applied below test according to rod inspection processureand IEC61109:1.Appearance2.Dimension inspection3.Dye penetration test4.Water difussion test5.Stress corrosion test(acid-resistant rod)6.Power frequency test7.40kV/10mm oil puncture test